You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

331 lines
9.9 KiB

<template>
<div class="address_edit">
<!-- 导航栏 -->
<!-- <div class="header_body"> -->
<!--<header-nav :slefBack="true" @goBack="goBack" :titelText="`详情`"></header-nav>-->
<!-- </div> -->
<!-- 中间 -->
<div class="warp_body">
2 years ago
<van-form @failed="onFailed" @submit="submit">
2 years ago
<van-cell-group>
<van-field
2 years ago
v-model="submitData.checkTime"
readonly
label="检查时间"
/>
<van-field
2 years ago
v-model="submitData.bureauDeptName"
readonly
label="执法部门"
/>
2 years ago
<!-- <van-field
2 years ago
v-model="submitData.checkItem"
label="检查事项"
rows="2"
readonly
type="textarea"
show-word-limit
/>
<van-field
2 years ago
v-model="submitData.checkRequire"
label="检查要求"
rows="2"
readonly
type="textarea"
show-word-limit
2 years ago
/>-->
<div class="fold-div">
<label>检查事项</label>
<van-text-ellipsis :content="submitData.checkItem" rows="2" autosize expand-text="展开" collapse-text="收起" />
</div>
<div class="fold-div">
<label>检查要求</label>
<van-text-ellipsis :content="submitData.checkRequire" rows="2" autosize expand-text="展开" collapse-text="收起" />
</div>
2 years ago
<!-- <van-field-->
<!-- v-model="submitData.enterpriseName"-->
<!-- label="企业名称"-->
<!-- readonly-->
<!-- />-->
<!-- <van-field-->
<!-- v-model="submitData.linkMan"-->
<!-- label="企业联系人"-->
<!-- readonly-->
<!-- />-->
<!-- <van-field-->
<!-- v-model="submitData.linkTel"-->
<!-- label="联系人电话"-->
<!-- :rules="[{ validator, message: '请输入正确内容' }]"-->
<!-- readonly-->
<!-- />-->
<van-field
v-if="!data.isEnterprise"
v-model="submitData.lawEnforcer"
readonly
label="执法人员"
/>
<van-field
v-if="!data.isEnterprise"
v-for="(item, index) in data.lawCer" :key="index"
v-model="item.show"
label="执法人员"
readonly
@click="showPopup"
/>
<!-- <van-field-->
<!-- v-model="submitData.remark"-->
<!-- label="备注"-->
<!-- rows="2"-->
<!-- autosize-->
<!-- type="textarea"-->
<!-- readonly-->
<!-- />-->
<van-action-bar v-if="!data.isEnterprise && submitData.isReg != 1 && submitData.status != 1 && submitData.status != 3">
<van-button round block type="info" native-type="submit" @click="cancel">取消</van-button>
</van-action-bar>
2 years ago
</van-cell-group>
</van-form>
2 years ago
</div>
<!-- <div class="warp_body">-->
<!-- <van-action-bar>-->
<!-- <van-action-bar-button text="保存" @click="submit" />-->
<!-- </van-action-bar>-->
<!-- </div>-->
<van-popup v-model:show="data.showLawEnforcerFlag" position="bottom" :style="{ height: '30%' }" />
<van-popup v-model:show="data.showTimePicker" position="bottom" :style="{ height: '30%' }" >
<van-date-picker
type="time"
@confirm="onConfirm"
@cancel="data.showTimePicker = false"
/>
</van-popup>
</div>
</template>
<script setup name="register">
import {getEnterpriseLawEnforcement, cancelEnterpriseLawEnforcement} from '../../api/administrative'
import { reactive, ref } from "vue";
import {getDict} from "../../api/Home";
import {queryLinkageById} from "../../api/linkage";
3 years ago
import {formattedTimeYYYYmmdd} from "@/util/util";
const router = useRouter();
const route = useRoute();
let queryaddressId = ref("");
const data = reactive({
showLawEnforcerFlag:false,
showTimePicker:false,
isEnterprise: false,
lawCer:[{ text:"", id:"" }],
});
//保存参数
let submitData = reactive({
/** 登记编号 */
lawEnforcementCode:"",
/** 企业名称 */
enterpriseName:"",
/** 企业ID */
enterpriseId:"",
/** 企业联系人 */
linkMan:"",
/** 联系人电话 */
linkTel:"",
/** 检查时间 */
checkTime:"",
/** 检查事项 */
checkItem:"",
/** 检查要求 */
checkRequire:"",
/** 执法部门 */
lawEnforcement:"",
/** 执法部门ID */
lawEnforcementId:"",
/** 执法人员 */
lawEnforcer:"",
/** 执法人员ID */
lawEnforcerId:"",
/** 执法人员2 */
lawEnforcerTwo:"",
/** 执法人员ID2 */
lawEnforcerTwoId:"",
/** 备注 */
remark:"",
/** 是否已登记 */
isReg:1,
/** 状态 0:正常;1:取消 */
status:1,
})
const onConfirm = (time) => {
if(time != null) {
var times = time.selectedValues;
submitData.checkTime = times[0] +"-"+ times[1] +"-"+ times[2];
}
data.showTimePicker = false;
};
const validator = (val) => /^1[34578]\d{9}$/.test(val);
const onFailed = (errorInfo) => {
console.log('failed', errorInfo);
};
// 返回
const goBack = () => {
router.go(-1);
};
const cancel = () => {
cancelEnterpriseLawEnforcement(route?.query?.id,success =>{
router.go(-1);
});
};
const setLinkageItem = (id) => {
queryLinkageById({"id": id}, success => {
submitData.checkItem = success.title
},error=>{});
}
const setLinkageGA = (id) => {
queryLinkageById({"id": id}, success => {
submitData.checkRequire = success.title
},error=>{});
}
//初始化参数,获取扫码的企业统一信用编码
onMounted(() =>{
data.isEnterprise = route?.query?.isEnterprise
getEnterpriseLawEnforcement(route?.query?.id,success =>{
//跳转企业二维码地址
if(success.success){
console.log("===> 0 : ", success.data)
submitData.lawEnforcementCode = success.data.lawEnforcementCode;
submitData.lawEnforcement = success.data.lawEnforcement;
submitData.lawEnforcer = success.data.lawEnforcer;
submitData.lawEnforcerTwo = success.data.lawEnforcerTwo;
// submitData.checkItem = success.data.checkItem;
// submitData.checkRequire = success.data.checkRequire;
submitData.checkItem = success.data.checkItemText;
submitData.checkRequire = success.data.checkRequireText;
submitData.enterpriseName = success.data.enterpriseName;
submitData.linkMan = success.data.linkMan;
submitData.linkTel = success.data.linkTel;
3 years ago
submitData.checkTime = formattedTimeYYYYmmdd(success.data.checkTime);
if(success.data.checkTimeOrder == 1){
submitData.checkTime = submitData.checkTime + " 上午 9:00~12:00";
}else{
submitData.checkTime = submitData.checkTime + " 下午 14:00~17:00";
}
submitData.remark = success.data.remark;
submitData.isReg = success.data.isReg;
submitData.status = success.data.status;
submitData.bureauDeptName = success.data.bureauDeptName;
submitData.bureauDeptId = success.data.bureauDeptId;
// 执法人员
submitData.lawEnforcerTwoId = success.data.lawEnforcerTwoId;
submitData.lawEnforcerTwo = success.data.lawEnforcerTwo;
var lawEnforcer2ShowStr = success.data.lawEnforcer2Show;
if ((null != submitData.lawEnforcerTwoId && submitData.lawEnforcerTwoId.length > 0)
&& (null != submitData.lawEnforcerTwo && submitData.lawEnforcerTwo.length > 0)) {
var tmpEnforceId = submitData.lawEnforcerTwoId.split(',');
var tmpEnforceText = submitData.lawEnforcerTwo.split(',');
var lawEnforcer2Show = lawEnforcer2ShowStr.split(',');
data.lawCer = [];
for (var i = 0; i < tmpEnforceId.length; i++) {
data.lawCer.push({text: tmpEnforceText[i], id: tmpEnforceId[i], show: lawEnforcer2Show[i]});
}
}
setLinkageItem(submitData.checkItem);
setLinkageGA(submitData.checkRequire);
}
},error=>{
console.log("登记失败")
})
})
</script>
<style lang="less" scoped>
.address_edit {
display: flex;
flex-direction: column;
height: 100%;
overflow: hidden;
2 years ago
background-color: #ebf3fb;
}
/* vant4的 Toast 和 Popup 样式冲突,会导致 Toast 变成白底 */
.van-popup.van-toast{
background: var(--van-toast-background) !important;
box-sizing: content-box !important;
/* 下面3条css,影响不大 */
transition: all var(--van-duration-fast) !important;
width: var(--van-toast-default-width) !important;
max-width: var(--van-toast-max-width) !important;
}
.van-popup.van-toast .van-toast__icon{
font-size: var(--van-toast-icon-size) !important;
}
.warp_body {
2 years ago
margin: 0 3%;
2 years ago
padding-bottom: 3rem;
2 years ago
width: 94%;
2 years ago
height: 100%;
2 years ago
background: #ebf3fb;
2 years ago
overflow-y: auto;
2 years ago
margin-top: 0.15rem;
}
:deep(.van-button) {
margin: 5% 3%;
padding: 0;
width: 94%;
height: 1rem;
color: #fff;
font-size: 0.4rem;
border-radius: 1rem;
background: #1367fe;
border: 1px solid #1367fe;
text-align: center;
}
/deep/ .van-action-bar {
box-shadow: 0 0 0.27rem #e5e5e5;
}
2 years ago
/deep/ .van-field__control:read-only {
cursor: default;
color: #666;
}
2 years ago
.fold-div {
position: relative;
display: flex;
margin: -1px 0.3rem 0;
padding: 0.05rem 0;
border-bottom: 1px solid #f6f7f8;
color: #323233;
font-size: 0.37rem;
}
.fold-div label {
width: 2.6rem;
padding: 0.27rem 0px 0.27rem 0.15rem;
}
2 years ago
2 years ago
.fold-div .van-text-ellipsis {
padding: 0.24rem 0;
width: calc(100% - 2.7rem);
color: #666;
}
</style>